Glycine receptor antibody | knockout validation | Synaptic Systems 146 011

This is a knockout-validated antibody summary, based on the publication "Loss of glycine receptors containing the α3 subunit compromises auditory nerve activity, but not outer hair cell function", as cited below [1]. Labome curates formal publications to compile a list of antibodies with unambiguous specificity within Validated Antibody Database (VAD).

Antibody information

Mouse monoclonal IgG1

Company: Synaptic Systems

Antibody: Glycine receptor

Catalog number: 146 011

Summary: Mouse monoclonal IgG1 against purified rat spinal cord glycine receptor. Reacts with human, rat, mouse, pig, and zebrafish. Suitable for western blot, immunoprecipitation, immunocytochemistry, immunohistochemistry, flow cytometry and ELISA.

Validation Method

Immunohistochemistry

Sample

Glra3+/+ and Glra3-/- mouse cochlea.

Secondary incubation

Cy3-conjugated secondary antibody from goat (Jackson ImmunoResearch Laboratories, Westgrove, PA, USA).

Detection

Specimens were photographed using an ApoTome microscope (Zeiss, Jena, Germany; objective: C-APOCHROMAT 40x / 1.2 W, numerical aperture: 1.2).

Figure

Immunostaining of cochlear cryosections from (a) Glra3+/+ and (b) Glra3-/- mice with the pan-GlyRα antibody mAb4a (red). Cell nuclei were stained with DAPI (blue). Scale bar: 20 µm. Please see Figure 1 in the article [1].

References
  1. Dlugaiczyk J, Hecker D, Neubert C, Buerbank S, Campanelli D, Becker C, et al. Loss of glycine receptors containing the α3 subunit compromises auditory nerve activity, but not outer hair cell function. Hear Res. 2016;337:25-34 pubmed publisher