product summary
Loading...
company name :
Rockland Immunochemicals
product type :
secondary antibody
product name :
Fluorescent TrueBlot®: Anti-Mouse Ig DyLight™ 800
catalog :
18-4517-32
quantity :
100 µL
price :
213.00 USD
more info or order :
citations: 3
Reference |
---|
product information
Catalog Number :
18-4517-32
Name :
Fluorescent TrueBlot®: Anti-Mouse Ig DyLight™ 800 - 18-4517-32
Display Name :
Fluorescent TrueBlot®: Anti-Mouse Ig DyLight™ 800
Application Note :
Fluorescent Mouse TrueBlot® Antibody DyLight™ 800 may also be used for detection in immunoassays that do not employ immunoprecipitation. Fluorescent Mouse TrueBlot® Antibody DyLight™ 800 is provided as a lyophilized powder. To conserve reagent, we recommend incubating the blots from minigels in sealed bags (removing as much air as possible) with minimal volume (2-3 mLs). If used conservatively at 2.5mls/blot will yield enough reagent for 40 blots. Note that there are three key procedural considerations: 1. Protein A or G beads may be used with the mouse, goat and sheep TrueBlot secondaries, but not with the rabbit TrueBlot secondary. Use of protein A or G beads with the rabbit TrueBlot will result in contaminating bands. 2. Immunoprecipitate should be completely reduced. 3. Bovine Serum Albumin or MB-070 Blocking Buffer for Fluorescent Western Blotting, at low concentrations, should be used as the blocking protein for the immunoblot. DO NOT USE BLOTTO or MILK. Note: To achieve best results when detecting mouse IgG1 subtypes, we recommend performing a dot blot or titration to determine the optimal dilution factor for your desired application. All recommended dilutions for listed applications are intended as an initial recommendation, specific conditions for each protein and antibody combination should be specifically optimized by the end user. Fluorescence technology is widely used to detect proteins. However, many common visible fluorophores often result in considerable background fluorescence in the visible range. Visible fluorophores are rarely used for membrane-based protein detection because of this high background. DyLight™ 800 and DyLight™ 680 antibody and reagent conjugates are specifically designed for protein detection methods that use longer-wavelength, near-infrared (IR) fluorophores to visualize proteins in western blotting and other applications. Very low background fluorescence in the IR range provides for a much higher signal-to-noise ratio than visible fluorophores. Detection levels in the picogram range on Western blots rival the sensitivity of chemiluminescence on film. DyLight™ 800 conjugates are optimized for the Odyssey® Infrared Imaging System developed by LI-COR. DyLight™ 800 conjugates are also suitable for immunofluorescence microscopy using commercially available excitation/emission filters in the 780nm/820nm range. Dual simultaneous labeling in western blots or microscopy is achieved when DyLight™ 800 conjugates are used in conjunction with DyLight™ 680 conjugates. DyLight™ 800 and DyLight™ 680 conjugates provide an ultra-sensitive and convenient alternative to standard chemiluminescent protein detection methods, as well as a valuable tool for multicolor imaging.
Buffer :
0.02 M Potassium Phosphate, 0.15 M Sodium Chloride, pH 7.2
Clonality :
Monoclonal
Clone ID :
eB144
Concentration Value :
1.0 mg/mL
Concentration Definition :
by UV absorbance at 280 nm
Conjugation :
DL800
Size :
100 µL
Default Unit :
ul
FLISA Dilution :
User Optimized
Flow Cytometry Dilution :
1:2,000 - 1:10,000
Fluorochrome Protein Value :
2.3
Immunohistochemistry Dilution :
User Optimized
IF Microscopy Dilution :
1:500 - 1:2,500
Western Blot Dilution :
1:1000
Expiration :
Expiration date is one (1) year from date of opening.
Format :
IgG
Host Animal :
Rat
General Disclaimer Note :
This product is for research use only and is not intended for therapeutic or diagnostic applications. Please contact a technical service representative for more information. All products of animal origin manufactured by Rockland Immunochemicals are derived from starting materials of North American origin. Collection was performed in United States Department of Agriculture (USDA) inspected facilities and all materials have been inspected and certified to be free of disease and suitable for exportation. All properties listed are typical characteristics and are not specifications. All suggestions and data are offered in good faith but without guarantee as conditions and methods of use of our products are beyond our control. All claims must be made within 30 days following the date of delivery. The prospective user must determine the suitability of our materials before adopting them on a commercial scale. Suggested uses of our products are not recommendations to use our products in violation of any patent or as a license under any patent of Rockland Immunochemicals, Inc. If you require a commercial license to use this material and do not have one, then return this material, unopened to: Rockland Inc., P.O. BOX 5199, Limerick, Pennsylvania, USA.
Packing Type :
Ambient
Physical State :
Lyophilized
Preservative :
0.01% (w/v) Sodium Azide
Purity and Specificity :
Fluorescent Mouse TrueBlot® Antibody DyLight™ 800 Conjugate was prepared from tissue culture supernatant by Protein G affinity chromatography. Assay by Immunoelectrophoresis resulted in a single precipitin arc against Anti-Mouse Serum. Reactivity is observed against native Mouse IgG by both Western blot and ELISA.
Reconstitution Buffer :
Restore with deionized water (or equivalent)
Reconstitution Volume :
100 µL
Species Reactivity :
Mouse
Stabilizer :
10 mg/ml Polyethylene Glycol (PEG-8000)
Storage :
Store vial at 4 °C prior to restoration. For extended storage aliquot contents and freeze at -20 °C or below. Avoid cycles of freezing and thawing. Centrifuge product if not completely clear after standing at room temperature. This product is stable for several weeks at 4 °C as an undiluted liquid. Dilute only prior to immediate use.
Synonyms :
Anti-Mouse IgG DL800, TrueBlot, DL800 TrueBlot ULTRA, DyLight™ 800 TrueBlot, TrueBlot for IP/WB, TrueBlot for immunoprecipitation, TrueBlot for western blotting, Fluorescent TrueBlot, Ms TrueBlot, Infrared, IR, NIR
Target Species :
Mouse
Background :
Mouse IgG TrueBlot® is a unique DyLight™ 800 conjugated Anti-mouse IgG monoclonal secondary antibody. Mouse IgG TrueBlot® enables detection of immunoblotted target protein bands, without hindrance by interfering immunoprecipitating immunoglobulin heavy and light chains. It is easy to generate publication-quality IP/Fluorescent Western Blot data with Mouse IgG TrueBlot®, simply substitute the conventional DL800 Anti-mouse IgG blotting reagent with Fluorescent Mouse TrueBlot® Antibody DyLight™ 800 and follow the prescribed protocol for sample preparation and immunoblotting. Mouse IgG TrueBlot® is ideal for use in protocols involving immunoblotting of immunoprecipitated proteins. TrueBlot preferentially detects the non-reduced form of mouse IgG over the reduced, SDS-denatured form of IgG. When the immunoprecipitate is fully reduced immediately prior to SDS-gel electrophoresis, reactivity of Mouse IgG TrueBlot® with the 55 kDa heavy chains and the 23 kDa light chains of the immunoprecipitating antibody is minimized thereby eliminating interference by the heavy and light chains of the immunoprecipitating antibody in IP/Western blot applications. Applications include studies examining post-translational modification (e.g., phosphorylation or acetylation) or protein-protein interactions.
Low Endotoxin :
No
Sample Size :
No
Application Text :
FLISA,Flow Cytometry,Immunohistochemistry,IF Microscopy,Western Blot,
Other :
User Optimized
Category :
Secondary Antibodies
Conjugation Name :
DyLight™ 800
2020 Price :
213.00 USD
Primary Image Name :
Fluorescent TrueBlot®: Anti-Mouse Ig DyLight 800 - Western Blot
more info or order :
company information

Rockland Immunochemicals
321 Jones Blvd
Pottstown, PA 19464
Pottstown, PA 19464
Info@rockland-inc.com
https://rockland-inc.com484-791-3823
headquarters: USA
Rockland Immunochemicals, Inc. produces Phosho-Site Specific Antibodies and Antibody based tools for basic, applied and clinical research. Our laboratory is located west of Philadelphia, Pennsylvania, USA. The technology base of the organization is the experience of its staff scientists in the production and purification of a wide range of antibodies through monoclonal & polyclonal antibody techniques utilizing in vitro and in vivo methods. Rockland's antibodies are suited for individuals performing Western Blotting, ELISA, Immunohistochemistry, Fluorescent Microscopy, High Content Screening and diagnostic kit production. Primary antibodies include Akt Pathway, Apolipoproteins, Apoptosis/Cell Cycle, Cytokines, Cell Signaling, Enzymes, Extracellular Matrix, Transcription Factors (NFkB) and Ubiquitin.