product summary
company name :
Protein Laboratories Rehovot
product type :
protein
product name :
Mouse stem cell factor (mSCF)
catalog :
CYT-54
product information
Title :
Mouse stem cell factor (mSCF)
Description :
Recombinant murine SCF produced in E.Coli is a single, non-glycosylated polypeptide chain containing 164 amino acids and having a molecular mass of 18309 Dalton. Bioactive mouse SCF appears as a non covalent homodimer (Lu et al. (1991) JBC, 266, 8102-8107).
Source :
E.Coli
Physical Appearance :
White lyophilized (freeze-dried) powder.
Formulation :
Lyophilized from a concentrated (1mg/ml) solution in water containing 0.02% NaHCO3.
Solubility :
It is recommended to reconstitute the lyophilized rHuSCF in sterile 18M-cm H2O not less than 100µg/ml, which can then be further diluted to other aqueous solutions conteining buffers and carrier proteins
Stability :
Lyophilized rmSCF although stable at room temperature for 3 weeks, should be stored desiccated below -18 C. Upon reconstitution rHuSCF should be stored at 4 C between 2-7 days and for future use below -18 C. For long term storage it is recommended to add a carrier protein (0.1% HSA or BSA). Please prevent freeze-thaw cycles.
Purity :
98.0% as determined by: (a) Analysis by RP-HPLC. (b) Anion-exchange FPLC. (c) Analysis by reducing and non-reducing SDS-PAGE Silver Stained gel. (d) Gel filtration chromatography under non denaturing conditions.
Amino Acid Sequence :
The sequence of the first five N-terminal amino acids was determined and was found to be Met-Lys-Glu-Ile-Cys.
Dimers and Aggregates :
Less than 2% as determined by gel filtration chromatography under non denaturing conditions.
Biological Activity :
PLR's mSCF is fully biologically active when compared to standard. The ED50 as determined by the dose-dependant stimulation of Human TF-1 cells is less then 2 ng/ml, corresponding to a Specific Activity of 105 IU/mg.
Endotoxin :
Less than 0.02 ng/µg (IEU/µg) of mSCF.
Protein content :
Protein content: Protein quantitation was carried out by UV spectroscopy at 280 nm using the absorbency value of 0.52 as the extinction coefficient for a 0.1% (1mg/ml) solution. This value is calculated by the PC GENE computer analysis program of protein sequences (IntelliGenetics).
Usage :
This material is offered by PLR for research, laboratory or further evaluation purposes.
company information
Protein Laboratories Rehovot
11 Hagefen Str.
Rehovot, 76349
Israel
http://www.plr-ltd.com
972-89489006
headquarters: Israel