product summary
Loading...
company name :
MyBioSource
product type :
ELISA/assay
product name :
Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1) ELISA Kit
catalog :
MBS2023241
quantity :
96 Strip Wells
price :
745 USD
more info or order :
product information
catalog number :
MBS2023241
products type :
ELISA Kit
products full name :
Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1) ELISA Kit
products short name :
Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1)
products name syn :
CD305; hLAIR1
other names :
leukocyte-associated immunoglobulin-like receptor 1 isoform a; Leukocyte-associated immunoglobulin-like receptor 1; leukocyte-associated immunoglobulin-like receptor 1; leukocyte-associated immunoglobulin-like receptor 1; CD_antigen: CD305
products gene name :
LAIR1
other gene names :
LAIR1; LAIR1; CD305; LAIR-1; CD305; LAIR-1; hLAIR1
uniprot entry name :
LAIR1_HUMAN
reactivity :
Human
sequence length :
209
specificity :
This assay has high sensitivity and excellent specificity for detection of Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1). No significant cross-reactivity or interference between Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1) and analogues was observed.
storage stability :
For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 degree C upon receipt while the others should be at 4 degree C. For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal. The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
other info1 :
Sample Types: Serum, plasma and other biological fluids. Detection Range: 0.313-20ng/mL. Sensitivity: The minimum detectable dose of this kit is typically less than 0.129ng/mL.
other info2 :
Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 . Intra-Assay: CV<10% . Inter-Assay: CV<12% . Assay Procedure Summary: 1. Prepare all reagents, samples and standards;. 2. Add 100uL standard or sample to each well. Incubate 2 hours at 37 degree C;. 3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37 degree C;. 4. Aspirate and wash 3 times;. 5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37 degree C;. 6. Aspirate and wash 5 times;. 7. Add 90uL Substrate Solution. Incubate 15-25 minutes at 37 degree C;. 8. Add 50uL Stop Solution. Read at 450nm immediately.
products description :
Principle of the Assay: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm 10nm. The concentration of Leukocyte Associated Immunoglobulin Like Receptor 1 (LAIR1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
ncbi gi num :
4504943
ncbi acc num :
NP_002278.1
ncbi gb acc num :
NM_002287.4
uniprot acc num :
Q6GTX8
ncbi mol weight :
23,049 Da
ncbi summary :
The protein encoded by this gene is an inhibitory receptor found on peripheral mononuclear cells, including natural killer cells, T cells, and B cells. Inhibitory receptors regulate the immune response to prevent lysis of cells recognized as self. The gene is a member of both the immunoglobulin superfamily and the leukocyte-associated inhibitory receptor family. The gene maps to a region of 19q13.4 called the leukocyte receptor cluster, which contains at least 29 genes encoding leukocyte-expressed receptors of the immunoglobulin superfamily. The encoded protein has been identified as an anchor for tyrosine phosphatase SHP-1, and may induce cell death in myeloid leukemias. Alternative splicing results in multiple transcript variants. [provided by RefSeq, Jan 2014]
size :
96 Strip Wells
price :
745 USD
more info or order :
company information
MyBioSource
P.O. Box 153308
San Diego, CA 92195-3308
sales@mybiosource.com
https://www.mybiosource.com
1-888-627-0165
headquarters: USA
MyBioSource, LLC was orginally founded in Vancouver by three enthusiastic scientists who are passionate about providing the world with the best reagents available. Together, they form a company with a big vision known as MyBioSource. MyBioSource is now located in San Diego, California, USA.

"MyBioSource's number 1 vision is to be the world's number 1 quality reagents provider."

Our goal is to provide researchers, scientists and customers alike with a one-stop-shop for all of their reagents needs, whether it is monoclonal antibody, polyclonal antibody, recombinant protein, peptide, etc...

"MyBioSource offers the best products at unbeatable prices."

Please spend a few minutes to browse our online catalogs and see the wide range of products available. We ship our products through our shipping/distribution facility in San Diego, California, USA.

Would you like to receive email and e-newsletter from MyBioSource about new products, special offers and events? Please click here to join our Mailing List!