catalog number :
MBS168884
products type :
Purification Kit
products full name :
LDL/VLDL and HDL Purification Kit (Ultracentrifugation Free)
products short name :
[LDL/VLDL and HDL]
products name syn :
[LDL/VLDL and HDL Purification Kit (Ultracentrifugation Free)]
storage stability :
Upon receipt store Dextran Removal Solution at room temperature. Store all other components at 4 degree C.
image1 heading :
Testing Data
image2 heading :
Testing Data #2
image3 heading :
Testing Data #3
image4 heading :
Testing Data #4
image5 heading :
Testing Data #5
products categories :
Metabolism Research; Lipoprotein Metabolism; Lipoprotein Purification Kits
products description :
Background/Introduction: Lipids are a diverse group of molecules that include monoglycerides, diglycerides, trigylcerides, fats, sterols, and others. Not only do lipids define and preserve cellular membrane integrity, but they are also involved in cellular processes such as membrane trafficking, signal transduction, apoptosis, and energy storage. Perturbation in the metabolism of lipids has been linked to many diseases such as cancer, diabetes, Alzheimer's disease, and coronary heart disease. In order to study lipids, they must often be extracted first from tissues or cellular cultures (1) and then quantified. Some methods for lipid quantification have been described that are quite sensitive, however they require expensive equipment such as an HPLC machine, light scattering detection technology, or a latroscan TLC-FID analyzer (2,3). ????????????????????????????????????????????' Lipid Quantification Kit (Fluorometric) specifically measures the neutral lipid content (see Figure 2) of samples using a lipid binding molecule that fluoresces brightly only when bound to lipids, resulting in a simple fluorescence readout. First, a crude or purified lipid source is applied to a 96-well plate. Then organic solvents are removed, followed by the addition of the fluorescent reagent. Lipid binding to the fluorescent reagent results in an increase in fluorescence that is easily detected on a microplate reader. This kit has a detection sensitivity of 3.9 mg/dL and is at least 10 times more sensitive than the Vanillin method (4). Each kit provides sufficient reagents to perform 100 assays including standards and unknown samples.
products references :
1. Atmeh R. F. (1990) J Lipid Res, 31: 1771-1780. References. 2. Havel R.J., Eder H.A., and Bragdon J.H. (1955) J. Clin. Invest, 34: 1345-1353. 3. Gaubatz J.W., Chari M.V., Nava M.L, Guyton J.R., and Morrisett J.D. (1987) J Lipid Res, 28: 69-79. 4. Kostner G.M., Ibovnik A., Holzer H., and Gillhofer H. (1999) J Lipid Res. 40: 2255-2263. 5. Hirowatari Y., Yoshida H., Kurosawa H., Shimura Y., Yanai H., and Tada N. (2010) J Lipid Res. 51: 1237-1243. 6. Lasser N.L., Roheim P.S., Edelstein D., and Eder H.A. (1973) J Lipid Res. 14: 1-8. 7. Camus M-C., Chapman M.J., Forgez P., and Laplaud P.M. (1983) J Lipid Res. 24: 1210-1228.