product summary
Loading...
company name :
Creative Diagnostics
product type :
ELISA/assay
product name :
Human Anti-PEG IgM ELISA Kit
catalog :
DEIASL244
quantity :
96T
more info or order :
product information
Catalog :
DEIASL244
proudctName :
Human Anti-PEG IgM ELISA Kit
common :
PEG
Short Name :
Human Anti-PEG IgM ELISA Kit
Common name :
PEG
Application :
Quantitative
Sample :
serum, plasma
Regulatory Status :
RUO
Size :
96T
Storage :
The reference stock, HRP conjugate and the PEG-BSA coated plate should be stored at - 20°C. All remaining kit components should be stored at 4°C. The microtiter plate should be kept in a sealed bag with desiccant. Kits will remain stable for six months from the date of purchase provided that the components are stored as described.
Target :
PEG
Species Reactivity :
human
Intended Use :
This kit is for research use only. Under no circumstances should it be used for therapeutic or human diagnostic applications.
General Description :
Attachment of polyethylene glycol (PEG) chains to therapeutic biologic agents, a process referred to as PEGylation, prolongs the circulating half-life of the modified protein by slowing proteolytic degradation and by masking it from the immune system. However, it has been reported that repeated injections of PEGylated proteins can induce anti-PEG antibodies that increase the rate of clearance and decrease drug efficacy (accelerated blood clearance, or ABC phenomenon). To aid research in this important area, we have developed a human anti-PEG IgM ELISA kit.
Principle Of The Test :
The assay uses immobilized mono mPEGylated BSA (20 kDa PEG chain) as the capture antigen (coated on microtiter wells) and horseradish peroxidase (HRP) conjugated anti-IgM monoclonal antibody (LDI clone 2C11-1-5 1 ) for detection. Serum or plasma samples are diluted and incubated alongside standards in the microtiter wells for 1 hour. The wells are subsequently washed, and HRP conjugate is added and incubated for 45 minutes. Anti-PEG IgM molecules are thus sandwiched between immobilized PEG and the detection antibody conjugate. The wells are then washed to remove unbound HRP-labeled antibodies. TMB reagent is added and incubated for 20 minutes at room temperature. This results in the development of a blue color. Color development is stopped by the addition of Stop Solution, changing the color to yellow. Optical density is measured spectrophotometrically at 450 nm. The concentration of anti-PEG IgM is proportional to the absorbance at 450 nm and is derived from a standard curve. This assay primarily detects antibodies directed against the polyoxyethylene backbone of PEG.
Reagents And Materials Provided :
1. PEG-BSA coated plate (12 x 8-wells). Store at -20°C 2. Anti-IgM HRP Stock. Store at -20°C 3. Anti-PEG Stock 2 (lyophilized). Store at -20°C 4. 20x HRP PEG Wash: PEGW50-20, 50 ml 5. HRP PEG Diluent: PEGD50-1, 50 ml 6. TMB: TMB11-1, 11 ml 7. Stop Solution: SS11-1, 11 ml
Materials Required But Not Supplied :
1. Pipettors and tips 2. Distilled or deionized water 3. Polypropylene or glass tubes 4. Vortex mixer 5. Absorbent paper or paper towels 6. Plate incubator/shaker 7. Plate washer 8. Plate reader capable of measuring absorbance at 450 nm. 9. Curve fitting software
Specimen Collection And Preparation :
In studies at Creative Diagnostics, Inc. we found anti-PEG IgM levels ranging from undetectable to>83,000 u/ml. Optimum dilutions must be determined empirically. However, we suggest testing samples at an initial dilution of 20-fold. To avoid matrix effects, do not use dilutions less than 20-fold.
Reagent Preparation :
WASH SOLUTION PREPARATION The wash solution is provided as a 20x stock. Prior to use, dilute the contents of the bottle (50 ml) with 950 ml of distilled or deionized water. STANDARD PREPARATION 1. The anti-PEG IgM standard is provided as a lyophilized stock. Reconstitute as described on the vial label. 2. Label 6 polypropylene or glass tubes as 100, 50, 25, 12.5, 6.25 and 3.125 u/ml. 3. In the tube labeled 100 u/ml prepare the 100 u/ml standard as detailed on the stock vial label. 4. Dispense 250 μl of diluent into the remaining tubes. 5. Prepare a 50 u/ml standard by diluting and mixing 250 μl of the 100 u/ml standard with 250 μl of diluent in the tube labeled 50 u/ml. 6. Similarly prepare the remaining standards by serial dilution. HRP CONJUGATE PREPARATION Approximately 5 minutes before needed, dilute the HRP conjugate stock with diluent (equilibrated to room temperature) as directed on the vial label.
Assay Procedure :
1. Secure the desired number of coated wells in the holder. 2. Dispense 100 μl of standards and diluted samples into the wells (we recommend testing in duplicate). 3. Incubate on a plate shaker at 150 rpm/25°C for 1 hour. 4. Aspirate the contents of the microtiter wells and wash the wells five times with 1x wash solution using a plate washer (400 μl/well). 5. Strike the wells sharply onto absorbent paper to remove all residual wash solution. 6. Add 100 μl of diluted HRP conjugate into each well. 7. Incubate on a plate shaker at 150 rpm/25°C for 45-minutes. 8. Wash as detailed above. 9. Dispense 100 μl of TMB into each well. 10. Incubate on a plate shaker at 150 rpm/25°C for 20-minutes. 11. Stop the reaction by adding 100 μl of stop solution to each well. 12. Gently mix. It is important to make sure that all the blue color changes to yellow. 13. Read the optical density at 450 nm with a microtiter plate reader within five minutes.
Calculation :
1. Using curve fitting software, construct a standard curve by plotting absorbance values of the standards versus concentration. 2. Fit the standard curve to an appropriate model (we fit to a quadratic equation) and determine concentration of the diluted samples from the standard curve. 3. Multiply the derived concentration by the dilution factor to determine concentration in the original samples. 4. If the A450 values of samples fall outside the standard curve, samples should be diluted appropriately and re-tested.
Typical Standard Curve :
A typical standard curve with optical density readings at 450nm on the Y-axis against anti-PEG IgM concentrations on the X-axis is shown below. This curve is for the purpose of illustration only and should not be used to calculate unknowns.
Parallelism :
To assess performance of the assay, two samples sample containing anti-PEG IgM at concentrations of 1226 and 2895 u/ml were serially diluted to produce values within the dynamic range of the assay.
Precautions :
1. Please read and instructions thoroughly before using the kit. 2. All reagents should be allowed to reach room temperature (25°C) before use. 3. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings. 4. Use only the wash solution and dilution buffer provided with the kit. PEG and PEGylated compounds are found in many buffers conventionally used in ELISA's and cannot be used with this kit. 5. Kits are validated using plate shakers set at 150 rpm and 25°C. Performance of the assay at lower temperatures and/or mixing speeds will likely result in lower absorbance values. 6. Optimal results are achieved if at each step, reagents are pipetted into the wells of the microtiter plate within 5 minutes.
Tetramethylbenzidine :
See the individual product datasheet
Sulfuric acid :
See the individual product datasheet
Sodium Azide :
See the individual product datasheet
Hydrochloric aci :
See the individual product datasheet
Others :
See the individual product datasheet
more info or order :
company information

Creative Diagnostics
NY, USA
contact@creative-diagnostics.com
http://www.creative-diagnostics.com1-631-624-4882
headquarters: USA
Creative Diagnostics is a leading manufacturer and supplier of antibodies, viral antigens, innovative diagnostic components, and critical assay reagents. We provide contract biologic R&D and manufacturing services to the diagnostic manufacturers along with GMP biologics manufacturing for the biopharmaceutical market. Our goal is to be a trusted source for all your assay development and manufacturing needs.
We also assist clients with rapidly developing, manufacturing, and commercializing point of care lateral flow, flow through, and ELISA assays. Our specialties are producing fluorescent, visual colloidal gold, and paramagnetic labels, and highly sensitive, quantitative, and reader-based tests.
With decades of experiences and our unique technologies, Creative Diagnostics is committed to providing its customers the highest quality products and services.
We also assist clients with rapidly developing, manufacturing, and commercializing point of care lateral flow, flow through, and ELISA assays. Our specialties are producing fluorescent, visual colloidal gold, and paramagnetic labels, and highly sensitive, quantitative, and reader-based tests.
With decades of experiences and our unique technologies, Creative Diagnostics is committed to providing its customers the highest quality products and services.