product summary
Loading...
company name :
Creative Diagnostics
product type :
ELISA/assay
product name :
Intact MMAE ADC ELISA Kit
catalog :
DEIABL314
quantity :
96T
product information
Catalog :
DEIABL314
proudctName :
Intact MMAE ADC ELISA Kit
common :
MMAE
Short Name :
Intact MMAE ADC ELISA Kit
Detection Method :
sELISA
Common name :
MMAE
Species :
Human
Application :
Quantitative
Sample :
Serum, plasma
Size :
96T
Storage :
This test kit must be stored at 2°C~8°C upon receipt. For the expiration date of the kit refer to the label on the kit box. All components are stable until this expiration date.
Specificity :
This MMAE-ADC ELISA doesn't show any cross reactivity to DM1- ADC or SN38-ADC.
Target :
MMAE
Species Reactivity :
Human
Alternative Names :
Monomethyl auristatin E; MMAE Antibody Drug Conjugate; MMAE
Intended Use :
This highly sensitive "sandwich" test kit is intended for use in the quantitative determination of MMAE Antibody Drug Conjugate level in human serum or plasma. It is useful for pre-clinical and clinical pharmacology study of MMAE Antibody Drug Conjugate (ADC).
Principle Of The Test :
This ELISA kit is designed, developed and produced for the quantitative measurement of MMAE Antibody Drug Conjugate in human serum or plasma. The assay utilizes the sandwich immunoassay technique with an antibody that binds to MMAE. Briefly, Anti-MMAE antibody is coated onto a microtiter plate. In the assay system, the assay calibrators, controls and test specimen are added to this microtiter plate. During the first incubation period, the anti-MMAE antibody captures the MMAE-Antibody Conjugate of calibrators, controls and test samples. Unbound proteins are washed away with a wash step. A HRP (horseradish peroxidase) conjugate anti-human IgG tracer antibody is added to each well of the microtiter plate. After the second incubation, a "sandwich" immunocomplex of "Anti-MMAE antibody – MMAE Antibody Conjugate – HRP-conjugated anti-human IgG antibody" is formed and attached to the wall of the plate. The unbound HRP-conjugated antibody is removed in a subsequent washing step. For the detection of this immunocomplex, each well is then incubated with a substrate solution in a timed reaction and then measured in a spectrophotometric microplate reader. The enzymatic activity of the immunocomplex bound to MMAE Antibody Conjugate on the wall of the microtiter well is directly proportional to the amount of MMAE Antibody Conjugate level in the sample.
Reagents And Materials Provided :
Prior to use allow all reagents to come to room temperature. Regents from different kit lot numbers should not be combined or interchanged. 1. Anti-MMAE Antibody Coated Microplate. One microplate with twelve by eight strips (96 wells total) coated with Anti-MMAE antibody. The plate is framed and sealed in a foil zipper bag with a desiccant. This reagent should be stored at 2 - 8 °C and is stable until the expiration date on the kit box. 2. MMAE Tracer Antibody. One vial containing 12mL of ready to use MMAE Tracer Antibody in a stabilized protein matrix. This reagent should be stored at 2-8°C and is stable until the expiration date on the kit box. 3. ELISA Wash Concentrate. One bottle containing 50 mL of 20-fold concentrate. Before use the contents must be diluted with 950 mL of demineralized water and mixed well. Upon dilution, this yields a working wash solution containing a surfactant in phosphate buffered saline with a non-azide, non-mercury preservative. The diluted wash solution may be stored at room temperature and is stable until the expiration date on the kit box. 4. ELISA HRP Substrate. Two bottles containing 6 mL of tetramethylbenzidine (TMB) with hydrogen peroxide. This reagent should be stored at 2 - 8°C and is stable until the expiration date on the kit box. 5. ELISA Stop Solution. One bottle containing 12 mL of stop solution. This reagent may be stored at 2 - 8°C or room temperature and is stable until the expiration date on the kit box. 6. Assay Buffer. One bottle containing 12 mL ready-to-use buffer. It should be used according to the assay procedures. This reagent should be stored at 2 - 8°C and is stable until the expiration date on the kit box. 7. Antibody Conjugated Calibrator Zero. One vial containing 30 mL calibrator zero. This reagent is used for diluting the calibrator stock to make assay calibrators, as well as for diluting test samples. This reagent should be stored at 2-8°C and is stable until the expiration date on the kit box. 8. Antibody-MMAE Conjugated Calibrator Stock-Not provided in the kit (optional). One vial containing the calibration stock of MMAE Antibody Drug Conjugate which is Disitamab vedotin. The DAR is 3.5. Refer to the vial for exact concentration of the standard. This reagent should be stored at 2-8°C and is stable until the expiration date on the kit box.
Materials Required But Not Supplied :
1.Precision single channel pipettes capable of delivering 25 μL, 50 μL, 100 μL, etc. 2.Disposable pipette tips suitable for above volume dispensing. 3.Aluminum foil. 4.Deionized or distilled water. 5.Plastic microtiter well cover or polyethylene film. 6.ELISA multichannel wash bottle or automatic (semiautomatic) washing system. 7.Spectrophotometric microplate reader capable of reading absorbance at 450/620 nm.
Specimen Collection And Preparation :
Serum and plasma samples are suitable specimen for MMAE-ADC measurement. Only 10 μL of samples is required for a duplicate determination of MMAE-ADC with this test kit. No special preparation of individual is necessary prior to specimen collection. Samples should be collected by standard technologies of clinical laboratory practice and recommended by manufacturer of sample collection tube. Samples should be transferred to a clean test tube right after centrifugation and should be stored at 2 - 8°C if the assay is to be performed within 72 hours. Otherwise, samples should be stored at -20°C or below until measurement. Avoid more than three times freeze-thaw cycles of specimen. Do not use hemolyzed, hyperlipermic, heat-treated or any contaminated specimens.
Reagent Preparation :
1.Prior to use allow all reagents to come to room temperature. Reagents from different kit lot numbers should not be combined or interchanged. 2.ELISA Wash Concentrate must be diluted to working solution prior to use. 3.Using CD Calibrator Stock: Dilute the reconstituted calibration stock to 1:X* using the zero calibrator and then diluted to obtain a level six calibrator at 390 ng/mL. Further create calibrator level five to two by 1:3 serialdilutions to obtain these calibrators with concentrations of 130 ng/mL,43.3 ng/mL,14.4 ng/mL, 4.8 ng/mL. Assay calibrators should be used within 24 hours and should be stored below -20°C. Do not exceed 3 freeze-thaw cycles. * Another way to making Cal5 is that dilute stock to 1μg/mL first, and then pipette 390μL of 1μg/mL to 610μL Cal0 to get 390ng/mL. X* = the concentration of calibration stock / 390 The validation data of this test was generated by using CD Antibody-MMAE Conjugated Calibrator Stock. 4.When using own MMAE calibrator stock, the user may follow step3 (using CD calibrator stock) as a reference. Every ADC is created with different DARs and conjugation methods. It is recommended to make in- house calibration curve. 5.Each unknown sample needs to be diluted 1:100 using Antibody Conjugated Calibrator Zero.
Assay Procedure :
Notes: 1.It is recommended that all standards and unknown samples be assayed in duplicate. The average absorbance reading of each duplicate should be used for data reduction and the calculation of results. It is recommended to add external controls to each assay. 2.Keep light sensitive reagents in the original amber bottles. 3.Store any unused antibody coated strips in the foil zipper bag with desiccant to protect from moisture. 4.Careful technique and use of properly calibrated pipetting devices are necessary to ensure reproducibility of the test. 5.Incubation times or temperatures other than those stated in this insert may affect the results. 6.An orbital mixer with a larger orbit radius (e.g.> 1 cm) may be used at speeds of 400 to 450 rpm. 7.Avoid air bubbles in the microwell as this could result in lower binding efficiency and higher CV% of duplicate reading. 8.All reagents should be mixed gently and thoroughly prior to use. Avoid foaming. 9.If adapting this assay to automated ELISA system such as DS-2, DSX or Trituras, a procedural validation is necessary if there is any modification of the assay procedure. Procedure 1. Add 25 μL of calibrators and diluted 1:100 test samples into the designated microwells. Tap the plate gently. 2. Immediately add 100 μL of Assay Buffer. 3. Seal the plate wells securely, cover with foil or other material to protect from light, and rotate on an ELISA plate shaker (small orbit radius) at room temperature (22°C~28°C) for 1 hour at 400 to 450 rpm. 4. Wash each well 5 times by dispensing 350 μL of working wash solution into each well and then completely aspirating the contents. Alternatively, an automated microplate washer can be used. 5. Add 100 μL of MMAE Tracer Antibody to each well. Tap the plate gently. 6. Seal the plate wells securely, cover with foil or other material to protect from light, and rotate on an ELISA plate shaker (small orbit radius) at room temperature (22°C~28°C) for 30 minutes at 400 to 450 rpm. 7. Wash each well 5 times by dispensing 350 μL of working wash solution into each well and then completely aspirating the contents. Alternatively, an automated microplate washer can be used. 8. Add 100 μL of ELISA HRP Substrate into each of the wells. 9. Cover the plate with aluminum foil or other material to avoid exposure to light. Incubate plate static, at room temperature for 20 minutes. 10. Immediately add 100 μL of ELISA Stop Solution into each of the wells. Mix gently. 11. Read the absorbance at 450 nm with reference filter at 620 nm.
Quality Control :
To assure the validity of the results each assay should include adequate controls.
Calculation :
It is recommended to use the four-parameter standard curve fitting. 1.Calculate the average absorbance for each pair of duplicate test results. 2.The standard curve is generated by the corrected absorbance of all standard levels on the ordinate against the standard concentration. Appropriate computer assisted data reduction programs should be used for the calculation of results. The antibody-MMAE conjugate concentrations for the test samples are read directly from the standard curve using their respective corrected absorbance.
Typical Standard Curve :
A typical absorbance data and the resulting standard curve from this MMAE ADC ELISA are represented. This curve should not be used in lieu of standard curve generated with each assay.
Precision :
Intra-assay Precision (Precision within an assay): ≤10%. Inter-assay Precision (Precision between assays) : ≤15%.
Detection Range :
0-390ng/mL
Sensitivity :
The limit of quantitation(LOQ) was 30ng/mL, the concentration corresponding to the value obtained by test MMAE Antibody Drug Conjugate spiked to a low concentration of 30ng/mL under the precision CV<15% and the recovery in the range of 80-120%. Hook Effect 1μg/mL
Recovery :
The recovery of MMAE Antibody Drug Conjugate spiked to different levels throughout the range of the assay in related matrices was evaluated.
Precautions :
The reagents must be used in professional laboratory. Wear gloves while performing this assay and handle these reagents as if they are potentially infectious. Avoid contact with reagents containing TMB, hydrogen peroxide, or sulfuric acid. TMB may cause irritation to skin and mucous membranes and cause an allergic skin reaction. TMB is a suspected carcinogen. Sulfuric acid may cause severe irritation on contact with skin. Do not get in eyes, on skin, or on clothing. Do not ingest or inhale fumes. On contact, flush with copious amounts of water for at least 15 minutes. Use Good Laboratory Practices.
Limitations :
1.This assay requires serum sample for testing. Cell culture or tissue culture samples not yet validate. 2.For sample values greater than 390 μg/mL, it is recommended to re-assay samples with further dilution with calibrator zero. 3.The kit standards are based on MMAE conjugated antibody or ADC concentration. It is not based on free MMAE concentration. The MMAE-ADC in different linker and DAR may give different curve shift. 4.If a higher analytical test sensitivity is desired, a modification by increasing the test sample volume from 25 μl per well to 50 μl or 100 μl per well along with a longer first incubation time period would be very helpful. Please call for technical support.
Standard Curve :
A typical absorbance data and the resulting standard curve from this MMAE ADC ELISA are represented. This curve should not be used in lieu of standard curve generated with each assay.
Tetramethylbenzidine :
See the individual product datasheet
Sodium Azide :
See the individual product datasheet
Others :
See the individual product datasheet
company information
Creative Diagnostics
NY, USA
contact@creative-diagnostics.com
http://www.creative-diagnostics.com
1-631-624-4882
headquarters: USA
Creative Diagnostics is a leading manufacturer and supplier of antibodies, viral antigens, innovative diagnostic components, and critical assay reagents. We provide contract biologic R&D and manufacturing services to the diagnostic manufacturers along with GMP biologics manufacturing for the biopharmaceutical market. Our goal is to be a trusted source for all your assay development and manufacturing needs.
We also assist clients with rapidly developing, manufacturing, and commercializing point of care lateral flow, flow through, and ELISA assays. Our specialties are producing fluorescent, visual colloidal gold, and paramagnetic labels, and highly sensitive, quantitative, and reader-based tests.
With decades of experiences and our unique technologies, Creative Diagnostics is committed to providing its customers the highest quality products and services.