product summary
Loading...
company name :
Creative Diagnostics
product type :
ELISA/assay
product name :
Anti-Tirzepatide ELISA Kit
catalog :
DEIA-JY25291
quantity :
96T
more info or order :
product information
Catalog :
DEIA-JY25291
proudctName :
Anti-Tirzepatide ELISA Kit
common :
Tirzepatide
Short Name :
Anti-Tirzepatide ELISA Kit
Detection Method :
sELISA
Common name :
Tirzepatide
Species :
Human
Application :
Quantitative
Sample :
Serum, Plasma (EDTA, Heparin)
Size :
96T
Storage :
The unopened kit is stable for at least 12 months from the date of manufacture at 2°C to 8°C, and the opened kit is stable for up to 1 month from the date of opening at 2°C to 8°C.
Species Reactivity :
Human
Intended Use :
This kit is designed for the quantitative detection of Anti-Tirzepatide in serum and plasma
Principle Of The Test :
Solid phase enzyme-linked immunosorbent assay (ELISA) based on the sandwich principle. Controls and samples (serum or plasma) are incubated in the microtiter plate coated with the reactant for Tirzepatide
Reagents And Materials Provided :
1. Pre-coated Microplate: 1 plate, 2-8°C 2. Standards: 2 vials, -20°C/2-8°C. Note: It is strongly recommended to use standards that are identical to the analyte in the samples . If this is not possible, the standards provided with the kit may be used. 3. Sample Diluent: 15 mL, 2-8°C 4. HRP-Conjugated Antibody: 10 mL, 2-8°C 5. TMB Substrate: 10 mL, 2-8°C 6. Stop Solution: 10 mL, 2-8°C 7. Wash Buffer (20X): 30 mL, 2-8°C 8. Plate Sealer: 2 sheets
Materials Required But Not Supplied :
1. Fresh matrix 2. Microplate reader capable of measurement at 450 nm with the correction wavelength set at 630 nm 3. Data analysis and graphing software. It is recommended to use software which is capable of generating a four-parameter logistic (4-PL) curve-fit 4. Automated microplate washer 5. Deionized or distilled water 6. Graduated cylinder 7. Plastic container 8. Tubes to aliquot and dilute samples 9. 10 μL, 200 μL, and 1000 μL precision pipettes and pipette tips 10. Multichannel pipettes 11. Disposable reagent reservoir 12. Absorbent paper 13. Lboratory timer 14. Refrigerator 15. Centrifuge 16. 25 ± 2 °C and 37± 2 °C incubator 17. Rotary shaker
Reagent Preparation :
Procedure Notes: 1. Any improper handling of samples or modification of the test procedure may influence the results. The indicated pipetting volumes, incubation times, temperatures and pre-treatment steps must be performed strictly according to the instructions. Use calibrated pipettes and devices only. 2. Once the test has been started, all steps should be completed without interruption. Make sure that required reagents, materials and devices are prepared ready at the appropriate time. Allow all reagents and specimens to reach room temperature (18-25°C) and gently swirl each vial of liquid reagent and sample before use. Mix reagents without foaming. 3. Avoid contamination of reagents, pipettes and wells/tubes. Use new disposable plastic pipette tips for each reagent, standard or specimen. Do not interchange caps. Always cap not used vials. Do not reuse wells/tubes or reagents. 4. Use a pipetting scheme to verify an appropriate plate layout. 5. Incubation time affects results. All wells should be handled in the same order and time sequences. It is recommended to use an eight-channel micropipette for pipetting of solutions in all wells. 6. Microplate washing is important. Improperly washed wells will give erroneous results. It is recommended to use a multichannel pipette or an automatic microplate washing system. Do not allow the wells to dry between incubations. Do not scratch coated wells during rinsing and aspiration. Rinse and fill all reagents with care. While rinsing, check that all wells are filled precisely with wash buffer, and that there are no residues in the wells. 7. Humidity affects the coated wells/tubes. Do not open the pouch until it reaches room temperature. Unused wells/tubes should be returned immediately to the resealed pouch including the desiccant. Component: Wash buffer (Must be prepared before starting assay procedure) Dilute: 10 mL (e.g.) With Distilled water: Up to 200 mL Dilution Ratio: 1/20 Remarks: Warm up 37°C to dissolve crystals. Mix vigorously Storage: 2-8°C Stability: 2 weeks Dilution of samples Sample: Serum/Plasma Diluent: Assay buffer Patient samples with a concentration of drug above the measuring range are to be rated as > "Highest Standard (Standard 1)". The result must not be extrapolated. The patient sample in question should be further diluted with assay buffer and retested.
Assay Procedure :
1. Pipette 100 μL of each "Standards" and diluted samples into the respective wells of microtiter plate Wells A1: Standard 1 B1: Standard 2 C1: Standard 3 D1: Standard 4 E1: Standard 5 F1: Standard 6 2. - Cover the plate with adhesive foil - Briefly mix contents by gently shaking the plate - Incubate 60 minutes at room temperature (18-25°C) 3. - Remove adhesive foil - Discard incubation solution - Wash plate three times each with 300 μL "Wash Buffer" - Remove excess solution by tapping the inverted plate on a paper towel 4. Pipette 100 μL "Conjugate" into each well 5. - Cover the plate with adhesive foil - Incubate 30 minutes at room temperature (18-25°C) 6. - Remove adhesive foil - Discard incubation solution - Wash plate three times each with 300 μL "Wash Buffer" - Remove excess solution by tapping the inverted plate on paper towel 7. - Pipette 100 μL "Substrate" into each well 8. - Incubate 15 minutes without adhesive foil at room temperature (18-25°C) in the dark 9. - Stop the substrate reaction by adding 100 μL "Stop Solution" into each well. Briefly mix contents by gently shaking the plate Colour changes from blue to yellow 10. Measure optical density with a photometer at OD 450 nm with reference wavelength 650 nm (450/650 nm) within 30 minutes after pipetting the "Stop Solution
Quality Control :
For a valid study, the OD 450/650 of the highest standard should be> 1.500 and the OD 450/650 of the lowest standard should be Expiration dates of reagents, storage conditions, pipettes, devices, incubation conditions, washing methods, etc.
Calculation :
1. Create a standard curve by using the standards. OD 450/650 nm for each standard on the vertical (Y-axis) axis versus the corresponding drug concentration on the horizontal (X-axis) axis. 2. The concentration of the samples can be read directly from this standard curve. Using the absorbance value for each sample, determine the corresponding concentration of drug from the standard curve. Find the absorbance value on the Y-axis and extend a horizontal line to the curve. At the point of intersection, extend a vertical line to the X-axis and read the drug concentration of the unknown sample. 3. If computer data is going to be used, we recommend primarily "Four Parameter Logistic (4PL)" or secondly the "point-to-point calculation". 4. To obtain the exact values of the samples, the concentration determined from the standard-curve must be multiplied by the dilution factor (10×). Any sample reading greater than the highest standard should be further diluted appropriately with assay buffer and retested. Therefore, if the pre-diluted samples have been further diluted, the concentration determined from the standard curve must be multiplied by the further dilution factor.
Performance Characteristics :
Intra-assay and inter-assay CVs < 30%
Recovery :
< 100 ± 30%
Precautions :
1. For professional use only. 2. Obey lot number and expiry date. Do not mix reagents of different lots. Do not use expired reagents. 3. Before starting the assay, read the instructions completely and carefully. Use the valid version of the package insert provided with the kit. Be sure that everything is understood. For further information (clinical background, test performance, automation protocols, alternative applications, literature, etc.) please refer to the local distributor. 4. Follow good laboratory practice and safety guidelines. Wear lab coats, disposable latex gloves and protective glasses where necessary. 5. Reagents of this kit containing hazardous material may cause eye and skin irritations. 6. Chemicals and prepared or used reagents must be treated as hazardous waste according the national biohazard safety guidelines or regulations.
applicatons :
This kit is designed for the quantitative detection of Anti-Tirzepatide in serum and plasma
Contents of Kit :
1. Pre-coated Microplate: 1 plate, 2-8°C 2. Standards: 2 vials, -20°C/2-8°C. Note: It is strongly recommended to use standards that are identical to the analyte in the samples . If this is not possible, the standards provided with the kit may be used. 3. Sample Diluent: 15 mL, 2-8°C 4. HRP-Conjugated Antibody: 10 mL, 2-8°C 5. TMB Substrate: 10 mL, 2-8°C 6. Stop Solution: 10 mL, 2-8°C 7. Wash Buffer (20X): 30 mL, 2-8°C 8. Plate Sealer: 2 sheets
Tetramethylbenzidine :
See the individual product datasheet
Sulfuric acid :
See the individual product datasheet
Sodium Azide :
See the individual product datasheet
Hydrochloric aci :
See the individual product datasheet
Others :
See the individual product datasheet
more info or order :
company information

Creative Diagnostics
NY, USA
contact@creative-diagnostics.com
http://www.creative-diagnostics.com1-631-624-4882
headquarters: USA
Creative Diagnostics is a leading manufacturer and supplier of antibodies, viral antigens, innovative diagnostic components, and critical assay reagents. We provide contract biologic R&D and manufacturing services to the diagnostic manufacturers along with GMP biologics manufacturing for the biopharmaceutical market. Our goal is to be a trusted source for all your assay development and manufacturing needs.
We also assist clients with rapidly developing, manufacturing, and commercializing point of care lateral flow, flow through, and ELISA assays. Our specialties are producing fluorescent, visual colloidal gold, and paramagnetic labels, and highly sensitive, quantitative, and reader-based tests.
With decades of experiences and our unique technologies, Creative Diagnostics is committed to providing its customers the highest quality products and services.
We also assist clients with rapidly developing, manufacturing, and commercializing point of care lateral flow, flow through, and ELISA assays. Our specialties are producing fluorescent, visual colloidal gold, and paramagnetic labels, and highly sensitive, quantitative, and reader-based tests.
With decades of experiences and our unique technologies, Creative Diagnostics is committed to providing its customers the highest quality products and services.
